Restriction on Raw Space Stand Height and Hanging Structure

The Organisers may require amendments or variations to be made to the design plans or proposals before approving the same, or may withhold approval at its discretion. No custom-built stand shall be permitted at the Fair unless the plans and design proposals have been approved in writing by the Organiser. Raw space exhibitors must ensure that they and their contractors are fully aware of the following points when preparing design proposals. Failure to observe such rules can result in costly alterations on site being required by the AsiaWorld-Expo and/or the Organiser. In the worst case, the Organiser may prohibit the construction of the intended custom-built booth. Any charges so incurred will be entirely at the exhibitor’s expense:

(1).   The maximum booth construction / decoration height limit is 6m, inclusive of lighting truss, if applied. For booth construction / decoration exceeding 4m high, a suitable and sufficient Complex Risk Assessment; Complex Method Statement and a Registered Structure Engineers sign off is required once the stand has been constructed. The said sign off should reach Mr Paul Wan / Mr. John Ng, Design Operation Team, HKTDC, by 1800 hrs on the last move-in day (ie. 27 October 2008). Enquiries please call: (852) 2584-4114 or (852) 2584-4127.
     
(2).   Contractors shall be responsible for effecting insurance which shall cover (but not limit to) its workers, displays and stand materials against loss and damage, third party and public liabilities (including the occupier’s), and shall produce such insurance policy to the Organiser upon request.
     
(3).   Site measurements are given in metric. Exhibitors, upon arrival and before commencing construction work, are required to check if the site is set out as per floor plan issued by the Organiser, and to report any errors to the Organiser immediately. If the contractor does not report any errors to the Organiser immediately, the Organiser will not be liable to any errors once construction work has been started by the party lodging the claim without first reporting the error to the Organiser.
     
(4).   All structures built from ground must be able to stand alone without the absolute use of hanging points.
     
(5).   No parts of any structures may extend beyond the boundaries of the site allocated. These may include but not limit to exhibits, Exhibitor’s name or logo.
     
(6).  

No suspensions are to be made from the ceiling of the Exhibition Hall, nor may any fixings be made to the floor, walls or any other parts of the building.

     
(7).  

The name and/or booth number of the Exhibitors must be prominently displayed and faced to aisle. If this rule is not observed, the Organisers reserves the right to affix them as they consider fit and to charge the cost incurred to the Exhibitor.

     
(8).  

Any signage and visual at height over 2500 mm facing adjacent booth must be set back 500 mm from booth boundary.

     
(9).  

Exhibitors should provide, set up their booth’s partitions facing their own booth areas, aisles, and adjacent booths and finish and/or cover all exposed surfaces to an acceptable standard.

     
(10).  

The Organisers must be notified in advance of any changes to the type or colour of the floor covering provided. Any cost incurred must be borne by the exhibitor.

     
(11).  

All electrical fittings and wirings must be installed in compliance with Electricity (wiring) Regulation of Hong Kong Electricity Ordinance (Chapter 406).

     
(12).  

All lighting fixtures should be installed at least 2200mm above ground. If not, they should be well protected so as not to cause danger to the general public.

     
(13).  

Main switch and distribution board may be required to install within space area at Official Contractor’s discretion.

     
(14).  

All materials used in the construction and decoration of exhibition stands or set-ups shall be flame retardant and be subject to inspection by the AsiaWorld-Expo and/or the Organisers.

     
(15).   Paint spraying, welding and the use of electrical saw are strictly prohibited inside the Exhibition Hall.

We believe that you and your appointed contractor(s) will support us in this initiative in creating a safer working environment. To ensure a full compliance on the above rules, we will penalize offenders by refusing their participation in our future fairs, and forfeiting totally the site work deposits lodged with us.

Thank you for your kind understanding and cooperation in advance. Should you have any question, please contact Mr John Ng on (852)2584-4127 or Mr Jackson Leung on (852)2584-4117.


Hong Kong Trade Development Council